What is Blood Oxygenation?

Information about Blood Oxygenation

Pulse oximetry is a non-invasive method allowing the monitoring of the oxygenation of a patient's blood.

A sensor is placed on a thin part of the patient's anatomy, usually a fingertip or earlobe, or in the case of a neonate, across a foot, and a light containing both red and infrared wavelengths is passed from one side to the other. Changing absorbance of each of the two wavelengths is measured, allowing determination of the absorbances due to the pulsing arterial blood alone, excluding venous blood, skin, bone, muscle, fat, and (in most cases) fingernail polish. Based upon the ratio of changing absorbance of the red and infrared light caused by the difference in color between oxygen-bound (bright red) and oxygen unbound (dark red or blue, in severe cases) blood hemoglobin, a measure of oxygenation (the per cent of hemoglobin molecules bound with oxygen molecules) can be made.

Indication

This is useful in any setting where a patient's oxygenation is unstable, including intensive care, operating, recovery, emergency and hospital ward settings, pilots in unpressurized aircraft, for assessment of any patient's oxygenation, and determining the effectiveness of or need for supplemental oxygen. Assessing a patient's need for oxygen is the mose essential element to life; no human life thrives in the absence of oxygen (cellular or gross). Although pulse oximetry is used to monitor oxygenation, it cannot determine the metabolism of oxygen, or the amount of oxygen being used by a patient. For this purpose, it is necessary to also measure carbon dioxide (CO2) levels. It is possible that it can also be used to detect abnormalities in ventilation. However, the use of pulse oximetry to detect hypoventilation is impaired with the use of supplemental oxygen, as it is only when patients breathe room air that abnormalities in respiratory function can be detected reliably with its use. Therefore, the routine administration of supplemental oxygen may be unwarranted if the patient is able to maintain adequate oxygenation in room air, since it can result in hypoventilation going undetected.

History

In 1935 Matthes developed the first 2-wavelength ear O2 saturation meter with red and green filters, later switched to red and infrared filters. This was the first device to measure O2 saturation.

In 1949 Wood added a pressure capsule to squeeze blood out of ear to obtain zero setting in an effort to obtain absolute O2 saturation value when blood was readmitted. The concept is similar to today's conventional pulse oximetry but suffered due to unstable photocells and light sources. This method is not used clinically. In 1964 Shaw assembled the first absolute reading ear oximeter by using eight wavelengths of light. Commercialized by Hewlett Packard, its use was limited to pulmonary functions and sleep laboratories due to cost and size.

Pulse oximetry was developed in 1972, by Aoyagi at Nihon Kohden using the ratio of red to infrared light absorption of pulsating components at the measuring site. It was commercialized by BIOX/Ohmeda in 1981 and Nellcor in 1983. Nellcor Incorporated in 1982, and introduced it into the US operating room market in 1983. Prior to its introduction, a patient's oxygenation was determined by a painful arterial blood gas, a single point measure which typically took a minimum of 20-30 minutes processing by a laboratory. (In the absence of oxygenation, damage to the brain starts in 5 minutes with brain death in another 10-15 minutes). In the US alone, approximately $2 billion was spent annually on this measurement. With the introduction of pulse oximetry, a non-invasive, continuous measure of patient's oxygenation was possible, revolutionizing the practice of anesthesia and greatly improving patient safety. Prior to its introduction, studies in anesthesia journals estimated US patient mortality as a consequence of undetected hypoxemia at 2,000 to 10,000 deaths per year, with no known estimate of patient morbidity.

By 1987, the standard of care for the administration of a general anesthetic in the US included pulse oximetry. From the operating room, the use of pulse oximetry rapidly spread throughout the hospital, first in the recovery room, and then into the various intensive care units. Pulse oximetry was of particular value in the neonatal unit where the patients do not thrive with inadequate oxygenation, but also can be blinded with too much oxygen. Furthermore, obtaining an arterial blood gas from a neonatal patient is extremely difficult.

In 1989, Diab and Kiani at Masimo Corporation invent Signal Extraction Pulse Oximetry (Masimo SET) using many proprietary breakthrough technologies and algorithms to separate the arterial signal from the non-arterial noise (e.g. venous blood movement during motion). The result was the first pulse oximetry technology scientifically and clinically proven to be accurate during conditions of patient motion and low perfusionThe technology was launched commercially in 1995.

With SET technology as the foundation, Masimo introduced a new oximetry technology in 2005 called pulse co-oximetry that allows clinicians to go beyond oxygen saturation to continuously and non-invasively measure carboxyhemoglobin, methemoglobin, pulse rate pleth variability index, and perfusion index. Called Rainbow SET technology, it uses multiple (7+) wavelengths of light and sophisticated signal processing including parallel engines and adaptive filters to calculate dyshemoglobin saturation values, allowing clinicians to detect and treat potentially life threatening conditions earlier than ever before.

Limitations

This is a measure solely of oxygenation, not of ventilation, and is not a substitute for blood gases checked in a laboratory as it gives no indication of carbon dioxide levels, blood pH, or sodium bicarbonate levels. The metabolism of oxygen can be readily measured by monitoring expired CO2. Saturation figures also give no information about blood oxygen content, as a patient can be severely anemic but still fully saturated.

Falsely low readings may be caused by hypoperfusion of the extremity being used for monitoring (often due to the part being cold or from vasoconstriction secondary to the use of vasopressor agents); incorrect sensor application; highly calloused skin; and movement (such as shivering), especially during hypoperfusion. To ensure accuracy, the sensor should return a steady pulse and/or pulse waveform. Falsely high or falsely low readings will occur when hemoglobin is bound to something other than oxygen. In cases of carbon monoxide poisoning, the falsely high reading may delay the recognition of hypoxemia (low blood oxygen level). Methemoglobinemia characteristically causes pulse oximetry readings in the mid-80s. Cyanide poisoning can also give a high reading because it reduces oxygen extraction from arterial blood (the reading is not false, as arterial blood oxygen is indeed high in early cyanide poisoning).

It should be noted that pulse oximetry only reads the percentage of bound hemoglobin. It can be bound to other gasses such as carbon monoxide and still read high even though the patient is hypoxic.The only noninvasive methodology that allows for the continuous and noninvasive measurement of the dyshemoglobins carboxyhemoglobin and methemoglobin is called pulse co-oximetry.

See also

External links

The term non-invasive in medicine has two meanings:
  • A medical procedure which does not penetrate or break the skin or a body cavity, i.e., it doesn't require an (invasive) incision into the body or the removal of biological tissue.

..... Read more.
Oxygenation refers to the amount of oxygen in a medium. In blood it may be taken to be synonymous with saturation, which describes the degree to which the oxygen-carrying capacity of haemoglobin is utilised, normally 98-100%.
..... Read more.
Blood is a specialized biological fluid consisting of red blood cells (also called RBCs or erythrocytes), white blood cells (also called leukocytes) and platelets (also called thrombocytes) suspended in a complex fluid medium known as blood plasma.
..... Read more.
Anatomy (from the Greek ἀνατομία anatomia, from ἀνατέμνειν
..... Read more.
A finger is a type of digit, an organ of manipulation and sensation found in the hands of humans and other primates. Normally humans have five digits on each hand (exceptions are polydactyly, hypodactyly and digit loss).
..... Read more.
On the ear of humans and many other animals, the earlobe (lobulus auriculæ, sometimes simply lobe or lobule) is the soft lower part of the Cory Drosen's ear, similar in composition to the labia, or pinna.
..... Read more.
Red is any of a number of similar colors evoked by light consisting predominantly of the longest wavelengths of light discernible by the human eye, in the wavelength range of roughly 625–750 nm.
..... Read more.
Infrared (IR) radiation is electromagnetic radiation of a wavelength longer than that of visible light, but shorter than that of radio waves. The name means "below red" (from the Latin infra, "below"), red being the color of visible light with the longest wavelength.
..... Read more.
In physics, wavelength is the distance between repeating units of a propagating wave of a given frequency. It is commonly designated by the Greek letter lambda (λ). Examples of wave-like phenonomena are light, water waves, and sound waves.
..... Read more.
A material's absorption spectrum shows the fraction of incident electromagnetic radiation absorbed by the material over a range of frequencies. An absorption spectrum is, in a sense, the opposite of an emission spectrum.
..... Read more.
In spectroscopy, the absorbance A is defined as

,


where is the intensity of light at a specified wavelength λ that has passed through a sample (transmitted light intensity) and is the intensity of the light before it enters the sample
..... Read more.
Infrared (IR) radiation is electromagnetic radiation of a wavelength longer than that of visible light, but shorter than that of radio waves. The name means "below red" (from the Latin infra, "below"), red being the color of visible light with the longest wavelength.
..... Read more.
Hemoglobin, also spelled haemoglobin and abbreviated Hb, is the iron-containing oxygen-transport metalloprotein in the red blood cells of the blood in vertebrates and other animals.
..... Read more.
Oxygenation refers to the amount of oxygen in a medium. In blood it may be taken to be synonymous with saturation, which describes the degree to which the oxygen-carrying capacity of haemoglobin is utilised, normally 98-100%.
..... Read more.
Hemoglobin, also spelled haemoglobin and abbreviated Hb, is the iron-containing oxygen-transport metalloprotein in the red blood cells of the blood in vertebrates and other animals.
..... Read more.
Oxygenation refers to the amount of oxygen in a medium. In blood it may be taken to be synonymous with saturation, which describes the degree to which the oxygen-carrying capacity of haemoglobin is utilised, normally 98-100%.
..... Read more.
Intensive Care Medicine or critical care medicine is a branch of medicine concerned with the provision of life support or organ support systems in patients who are critically ill and who usually require intensive monitoring.
..... Read more.
Aviator (common usage term: pilot, regulatory usage term: airman) is a person qualified in the operation of aircraft, whether for pleasure or as a profession.
..... Read more.
2, −1
(neutral oxide)
Electronegativity 3.44 (Pauling scale)
Ionization energies
(more) 1st: 1313.9 kJmol−1
2nd: 3388.3 kJmol−1
3rd: 5300.5 kJmol−1

Atomic radius 60 pm
Atomic radius (calc.
..... Read more.
Carbon dioxide is a chemical compound composed of two oxygen atoms covalently bonded to a single carbon atom. It is a gas at standard temperature and pressure and exists in Earth's atmosphere in this state.
..... Read more.
MeSH D007040 In medicine, hypoventilation (also known as respiratory depression) occurs when ventilation is inadequate (hypo means "below") to perform needed gas exchange.
..... Read more.
19th century - 20th century - 21st century
1900s  1910s  1920s  - 1930s -  1940s  1950s  1960s
1932 1933 1934 - 1935 - 1936 1937 1938

Year 1935 (MCMXXXV
..... Read more.
19th century - 20th century - 21st century
1910s  1920s  1930s  - 1940s -  1950s  1960s  1970s
1946 1947 1948 - 1949 - 1950 1951 1952

Year 1949 (MCMXLIX
..... Read more.
Photosensors or photodetectors are sensors of light or other electromagnetic energy. There are several varieties:

Most optical detectors are quantum devices in which an individual photon produces a discrete effect.
..... Read more.
19th century - 20th century - 21st century
1930s  1940s  1950s  - 1960s -  1970s  1980s  1990s
1961 1962 1963 - 1964 - 1965 1966 1967

Also Nintendo emulator: 1964 (emulator).

..... Read more.
19th century - 20th century - 21st century
1940s  1950s  1960s  - 1970s -  1980s  1990s  2000s
1969 1970 1971 - 1972 - 1973 1974 1975

Year 1972 (MCMLXXII
..... Read more.
19th century - 20th century - 21st century
1950s  1960s  1970s  - 1980s -  1990s  2000s  2010s
1978 1979 1980 - 1981 - 1982 1983 1984

Year 1981 (MCMLXXXI
..... Read more.
19th century - 20th century - 21st century
1950s  1960s  1970s  - 1980s -  1990s  2000s  2010s
1980 1981 1982 - 1983 - 1984 1985 1986

Year 1983 (MCMLXXXIII
..... Read more.
This article or section may contain original research or unverified claims.
Please help Wikipedia by adding references. See the for details.
This article has been tagged since September 2007.
The creation of Dr.
..... Read more.
19th century - 20th century - 21st century
1950s  1960s  1970s  - 1980s -  1990s  2000s  2010s
1979 1980 1981 - 1982 - 1983 1984 1985

Year 1982 (MCMLXXXII
..... Read more.